******** Audi Q7 Quattro (4LB) V6-3.0L DSL Turbo (CATA) Technical DIAGNOSIS AND REPAIR # 901124 Date: 110613


Instruments - Clock Is Inaccurate



90 - A6, Q7 clock inaccurate



90 11 24



2026348/2



June 13, 2011



Supersedes Technical DIAGNOSIS AND REPAIR Group 90 number 11 - 23 dated May 10, 2011 for reasons listed below.



211



Affected Vehicles



Condition



Customer indicates the clock in the vehicle is too fast or too slow.



Technical Background



Time deviations of approximately 1 second per day (half a minute per month) are permitted. In some cases the deviation may be greater.



Production Solution



Optimized software 214 in J285 with improved clock accuracy planned for model year 2012.



Service



1. If the time deviation exceeds 1 second per day, perform the SVM update to J285.



SVM Update Instructions



1. Follow all instructions in the attached TSB 2011732 00 Software Version Management (SVM), operating instructions.



2. Update the instrument cluster (J285) using the SVM action code 17A005.



Note:



On some vehicles after the software update, DTC 12814 (Instrument Cluster Control Module No Communication - Sporadic) may appear in the 02



module. This code cannot be cleared using GFF and must be cleared using Vehicle Self Diagnosis. Clear the DTC before releasing the vehicle back



to the customer.



212



WARRANTY



ADDITIONAL INFORMATION



The following Technical DIAGNOSIS AND REPAIR will be necessary to complete this procedure:



^ TSB 2011732 00 Software Version Management (SVM), operating instructions.



All parts and service references provided in this TSB are subject to change and/or removal. Always check with your parts Department and service



manuals for the latest information.



ATTACHMENT



213



214



215



216



217



218



TSB 2011732 00 Software Version Management (SVM), operating instructions

Monday, 12 November 2018

Instruments - Clock is Inaccurate


Instruments - Clock is Inaccurate



2002-2006 Mini Cooper (R50) L4-1.6L (W10) Page 93



SI M62 01 05



Instruments



November 2005



Technical Service



SUBJECT



Clock Inaccurate



MODEL



R50 (Cooper), R52 (Convertible), R53 (Cooper S)



SITUATION



The clock is either losing or gaining time, with vehicles typically showing a deviation of several minutes a week. In addition, there are occasional



cases where the clock resets by itself unable to adjust or stops counting.



No faults are stored in the Instrument Cluster.



CAUSE



Inaccurate calibration of the crystal frequency.



CORRECTION



In case of a customer complaint, run the diagnosis with DIS/GT1. If "Diagnosis" reveals no faults, then check that there are no volt drops in either



the Instrument Cluster power supply or ground circuits. In addition, check the integrity of the Instrument Cluster wiring and connectors.



If no faults are found, then replace the center Instrument Cluster (IKE). Do not replace the steering column gauges.



To confirm that an improved replacement part is being installed, check the build date label on the front of the Instrument Cluster. For parts produced



up to September 8, 2005, there is an additional "clock cal" sticker on the black plastic molding. For parts produced after September 8, 2005, all parts



are improved parts.



PARTS INFORMATION



Part Number Description Quantity



Refer to EPC Center Instrument 1



Center (IKE)



WARRANTY INFORMATION



Covered under the terms of the MINI New Vehicle limited Warranty.

Friday, 30 December 2016

******** Audi A6 Quattro Sedan (4F2) V6-3.0L SC (CCAA) Technical DIAGNOSIS AND REPAIR # 901124 Date: 110613


Instruments - Clock Is Inaccurate



90 - A6, Q7 clock inaccurate



90 11 24



2026348/2



June 13, 2011



Supersedes Technical DIAGNOSIS AND REPAIR Group 90 number 11 - 23 dated May 10, 2011 for reasons listed below.



268



Affected Vehicles



Condition



Customer indicates the clock in the vehicle is too fast or too slow.



Technical Background



Time deviations of approximately 1 second per day (half a minute per month) are permitted. In some cases the deviation may be greater.



Production Solution



Optimized software 214 in J285 with improved clock accuracy planned for model year 2012.



Service



1. If the time deviation exceeds 1 second per day, perform the SVM update to J285.



SVM Update Instructions



1. Follow all instructions in the attached TSB 2011732 00 Software Version Management (SVM), operating instructions.



2. Update the instrument cluster (J285) using the SVM action code 17A005.



Note:



On some vehicles after the software update, DTC 12814 (Instrument Cluster Control Module No Communication - Sporadic) may appear in the 02



module. This code cannot be cleared using GFF and must be cleared using Vehicle Self Diagnosis. Clear the DTC before releasing the vehicle back



to the customer.



WARRANTY



ADDITIONAL INFORMATION



The following Technical DIAGNOSIS AND REPAIR will be necessary to complete this procedure:



269



^ TSB 2011732 00 Software Version Management (SVM), operating instructions.



All parts and service references provided in this TSB are subject to change and/or removal. Always check with your parts Department and service



manuals for the latest information.



ATTACHMENT



270



271



272



273



274



275



TSB 2011732 00 Software Version Management (SVM), operating instructions