Instruments - Clock Is Inaccurate
90 - A6, Q7 clock inaccurate
90 11 24
2026348/2
June 13, 2011
Supersedes Technical DIAGNOSIS AND REPAIR Group 90 number 11 - 23 dated May 10, 2011 for reasons listed below.
268
Affected Vehicles
Condition
Customer indicates the clock in the vehicle is too fast or too slow.
Technical Background
Time deviations of approximately 1 second per day (half a minute per month) are permitted. In some cases the deviation may be greater.
Production Solution
Optimized software 214 in J285 with improved clock accuracy planned for model year 2012.
Service
1. If the time deviation exceeds 1 second per day, perform the SVM update to J285.
SVM Update Instructions
1. Follow all instructions in the attached TSB 2011732 00 Software Version Management (SVM), operating instructions.
2. Update the instrument cluster (J285) using the SVM action code 17A005.
Note:
On some vehicles after the software update, DTC 12814 (Instrument Cluster Control Module No Communication - Sporadic) may appear in the 02
module. This code cannot be cleared using GFF and must be cleared using Vehicle Self Diagnosis. Clear the DTC before releasing the vehicle back
to the customer.
WARRANTY
ADDITIONAL INFORMATION
The following Technical DIAGNOSIS AND REPAIR will be necessary to complete this procedure:
269
^ TSB 2011732 00 Software Version Management (SVM), operating instructions.
All parts and service references provided in this TSB are subject to change and/or removal. Always check with your parts Department and service
manuals for the latest information.
ATTACHMENT
270
271
272
273
274
275
TSB 2011732 00 Software Version Management (SVM), operating instructions