******** Audi A6 Quattro Sedan (4F2) V6-3.0L SC (CCAA) Technical Service Bulletin # 261215 Date: 121105


Emissions - MIL ON/DTC's P0491 and P0492 Set



01 MIL on (DTC P0491and P0492), stored at the same time



26 12 15



2026528/7



November 5, 2012.



Supersedes Technical Service Bulletin Group 26 number 12-10 dated March 30, 2012 for reasons listed below.



6



Affected Vehicles



Condition



^ MIL on.



^ DTC P0491 and P0492 (Secondary Air System Insufficient Flow, Bank 1/2) are stored at the same time.



^ Mileage greater than 20,000 miles.



Technical Background



Not applicable.



Production Solution



Not applicable.



Service



For A6 call Technical Assistance Center (TAC), for Audi Q5 and S4 follow below steps.



1. Delete all DTCs and bring engine to operating temperature.



2. Go into "Basic Setting" in VAS tester (VSD) and select "Secondary Air System Check".



To begin, start the test on the tester and then depress first brake pedal and the gas pedal, and then.



3. Observe MVB:



7



PRS_SA_DIF (note down value at 3sec of test - phase 1 of test, see Figure 1. Pressure test graph) MASS_SA_REL (at the end of test)



Note:



To restart the test you have to back out of VSD to the main screen and cycle the key.



4. Call Technical Assistance Center (TAC) with the results (2 values).



Warranty



8



Additional Information



All parts and service references provided in this TSB are subject to change and/or removal. Always check with your Parts Department and service



manuals for the latest information.