Audi A4 Quattro Wagon (8K5) L4-2.0L Turbo (CAEB) Technical Service Bulletin # 961228 Date: 120127
Antitheft - DTC 02811 After Repl. Steering Column Lock
96 DTC 02811 in Access Start Authorization Control unit after replacing Electronic Steering Column Lock J764
96 12 28
2028419/1
January 27, 2012.
275
Affected Vehicles
Condition
After the replacing the control unit for the electronic steering column lock (J764), the DTC entry "2811 - control unit for steering column lock
(electronic steering column lock) - incorrect cannot be cleared from the fault memory of the access start authorization control unit (J393), address
code 05.
Technical Background
There is a diagnostic software error in the access start authorization control unit (J393) which does not allow this DTC from being erased from the
fault memory. As a result the access start authorization control unit (J393) must have its software updated after the replacement of the electronic
steering column lock (J764) in order to allow the DTC to be erased from the (J393) control unit. Replacing the electronic steering column lock
(J764) a second time will not allow the DTC entry in the J393 to be erased.
Production Solution
Optimized software was placed in to production.
Service
Tip: Update the software of the access and start authorization (J393) control unit for BEFORE changing the electronic steering column lock (J764)
control unit a SECOND time. Replacing the electronic steering column lock control unit a second time will not be accepted by warranty. This control
unit should only be replaced a single time.
1. There are two possible variations of the access start authorization control unit (J393) and they can be recognized by the two different part
numbers, 8K0 907 064 XX & 8K0 907 289 X (where "X" & "XX" denote any part number suffix combination). Each part must be handled in a
different manner as suggested below. The reason for this is that not all part variations can support a software update.
2. For an access start authorization control unit (J393) with P/N 8K0 907 064, check the software version of the control unit and determine if the
software can be updated (see table below). Proceed to Step 4.
SVM Update Instructions
Follow all instructions in TSB 2011732 00 Software Version Management (SVM), operating instructions.
Update the comfort access start authorization/convenience control module (J393) using the SVM action code as listed in the table above. If the
software level is already at the level listed in the table, proceed to step 3.
3. For an access start authorization control units (J393) with P/N 8K0 907 289, only replacing the hardware can be performed. Please reference TSB
2024111 when replacing the control unit because one or two SVM Codes will be required to perform the SVM coding and parameterization of the
new control unit.
4. For P/N 8K0 907 064, if a software update is not possible or if the software level is already at the level listed in the table above, then replace the
276
access and start authorization (J393) control unit. Please reference TSB 2024111 when replacing the control unit because an SVM Code will be
required to perform the SVM coding and parameterization of the new control unit.
277
Warranty
Additional Information
The following Technical Service Bulletin will be necessary to complete this procedure:
^ TSB 2011732 00 Software Version Management (SVM), operating instructions
^ TSB 2024111 57 Replaced Comfort System control unit (BCM2) cannot be coded
All parts and service references provided in this TSB are subject to change and/or removal. Always check with your Parts Department and service
manuals for the latest information.