Thursday 15 November 2018

Computers/Controls - Progman V22.0 and V22.0.1 Errors


Computers/Controls - Progman V22.0 and V22.0.1 Errors



June 2006



Technical Service



SI M 09 04 06



Programming/Coding Explanation



SUBJECT



Release Notes Progman V22.0 and V22.0.1



MODEL



All



SITUATION



2002-2006 Mini Cooper (R50) L4-1.6L (W10) Page 222



Progman V22.0 and V22.0.1 have been released. Certain errors may occur during installation or usage.



CAUSE



Software error



COMPLAINT



The following issues are currently known:



1. "Back" button is missing after the "Change" button in the menu bar has been selected.



2. An incorrect CIP version may be displayed on the "Online update" screen after a JETStream update.



3. It may no longer be possible to use the GT1 after selecting "Update software".



4. In some cases, no status display (white screen) appears for a few minutes if a measures plan is cancelled.



5. No FASTA data has been transferred for a long period of time.



6. SSS enters service mode during the day, and it is no longer possible to start a session.



7. The user interface may show "# 4" following a full installation using Progman V21.2.



8. Retrofits and conversions may or may not be offered on vehicles with ZCS, even if they are or are not valid for the vehicle concerned.



9. Vehicle information may be exchanged between two simultaneous running sessions of same vehicle series.



10. Various errors may occur during replacement procedure.



PROCEDURE



1. Button is hidden behind the "Minimize" button, no workaround.



2. Ignore the incorrect CIP version displayed.



3. Proceed as follows: 1. Disconnect the GT1 cable and wait until an error message notifies you of the loss of connection. 2. Reconnect the cable.



3. Update the SSS list. 4. Select the SSS again and end the session in the usual way.



4. Wait until the next screen appears. This may take a few minutes.



5. Check all FASTA and online service settings. If everything is correct reinstall Progman. However, the existing FASTA data will be lost.



6. Go to "Operating Status" on the SSS, press "Cancel" and wait about 1-2 minutes.



7. Restart the system manually.



8. Ignore the retrofit and conversions offered in error.



9. Only program one vehicle of this series per SSS.



10. For replacement procedures use only one vehicle per SSS at a time.