Audi A4 Quattro Sedan (8K2) L4-2.0L Turbo (CAEB) Technical Service Bulletin # 971005 Date: 100521
Lighting - Park Lamps Stay On With Vehicle Locked
94 Parking lights remain on after vehicle is locked
97 10 05
2021911/2
May 21, 2010
Supersedes Technical Service Bulletin Group 97 number 09-09 dated November 4, 2009 for reasons listed below.
Affected Vehicles
Condition
^ With the headlight switch in the Auto position, after locking the vehicle, the parking lights are permanently on.
Audi A4 Quattro Sedan (8K2) L4-2.0L Turbo (CAEB) Page 561
^ In the Central Electrics Control Module J519 (address word 09), DTC 2071 (Local data bus electric fault in circuit) is stored as a sporadic fault.
Technical Background
The DTC entry can occur if the control unit receives a wake-up signal (for example, if the vehicle is unlocked using the remote key) during the
transition to sleep mode.
Production Solution
Optimized Central Electrics Control Module (J519) software.
Service
1. Follow all instructions in the attached TSB 2011732 00 Software Version Management (SVM), operating instructions.
2. Update the Central Electrics Control Module (J519) using the SVM action code as listed in the table above if necessary.
3. If an online update via SVM is not possible, use the Update CD listed in the Required Parts and Tools section below. After a successful update,
please perform an SVM transmission (spec-actual comparison) using the above SVM code.
Warranty
All warranty claims submitted for payment must be in accordance with the Audi Warranty Policies and Procedures Manual. Claims are subject to
review or audit by Audi Warranty.
Required Parts and Tools
Audi A4 Quattro Sedan (8K2) L4-2.0L Turbo (CAEB) Page 562
Audi A4 Quattro Sedan (8K2) L4-2.0L Turbo (CAEB) Page 563
Audi A4 Quattro Sedan (8K2) L4-2.0L Turbo (CAEB) Page 564
Audi A4 Quattro Sedan (8K2) L4-2.0L Turbo (CAEB) Page 565
Audi A4 Quattro Sedan (8K2) L4-2.0L Turbo (CAEB) Page 566
Audi A4 Quattro Sedan (8K2) L4-2.0L Turbo (CAEB) Page 567
Attachment - 00 Software Version Management (SVM), Operating Instructions