Saturday 19 June 2021

******** Audi Q7 Quattro (4LB) V6-3.0L DSL Turbo (CATA) Technical DIAGNOSIS AND REPAIR # 271210 Date: 120213


Battery - Testing/Charging On BDM Equipped Vehicles



27 Battery testing and charging - vehicles with BDM (J367)



27 12 10



2023282/2



February 13, 2012.



Supersedes Technical DIAGNOSIS AND REPAIR Group 27 number 10 - 05 dated May 5, 2010 for reasons listed below.



Affected Vehicles



166



Condition



Battery testing and charging for vehicles equipped with a Battery Data Manager (BDM - J367).



Technical Background



When the Incharge 940 is used as a battery charger in auto mode, it performs a battery condition test and may prematurely fail the battery if the



charging takes place at the jumper posts in the engine compartment. This is due to the added resistance in the system between the battery and jumper



posts. When the Incharge 940 is used as a battery charger in manual mode, the battery condition test is not performed.



Production Solution



Not applicable.



Service



TESTING THE BATTERY



VAS scan tool:



Follow Guided Fault Finding battery test plan in service work.



CHARGING THE BATTERY



Midtronics INC-940 diagnostic charging station:



Connect the charging station - auto mode



1. Connect the Incharge 940 positive cable clamp to the positive battery post.



167



2. Connect the negative cable clamp to the vehicles negative battery cable downstream at the body attachment point. (Figures 1 and 2 illustrate this



on an Audi Q5.)



Tip: This connection ensures J367 remains in the loop so that it may provide battery charge data to the Gateway (J533) as the J367 is clamped



directly to the battery negative post.



3. Enter the DIN value listed on the battery.



Connect the charging station - manual mode



1. Connect the Incharge 940 to the battery jumping posts in the engine compartment or as described in the auto mode section.



2. Enter the DIN value listed on the battery.



Tip: Please obtain the battery serial number (example: VAO 99050770MX), located on top of the battery, for battery testing or replacement and for



future reference or when contacting the Technical Assistance Center (TAC).



Warranty



This TSB is informational only and not applicable to any Audi warranty.



Additional Information



All parts and service references provided in this TSB are subject to change and/or removal. Always check with your Parts Department and service



manuals for the latest information.