Sunday 30 August 2020

******** Audi Q5 Quattro (8RB) V6-3.2L (CALB) Technical DIAGNOSIS AND REPAIR # 571159 Date: 111021


Body - Outer Door Seals Are Loose/Detached



57 Outer door seals loose



57 11 59



2019733/8



October 21, 2011.



Supersedes Technical DIAGNOSIS AND REPAIR Group 57 number 11 - 57 dated September 7, 2011 for reasons listed below.



Affected vehicles



Condition



283



The outer door seals have become partially detached.



Technical Background



Loss of adhesion between the door structure and door seal due to a flaw in the attachment process in production.



Production Solution



Optimized production process.



Service



In cases where the outer door seal has become partially detached, it may not be necessary to replace the outer door seal. Seals can be reattached



provided they are not damaged, have not been previously repaired or previously reattached and the detachment length does not exceed 10 cm.



1. Inspect all four doors.



^ All undamaged, previously unrepaired, or loose seals with a detachment length less than 10 cm will be repaired. Complete steps 2-9 below to



repair the door seals.



^ If the door seal is damaged, has been previously repaired, or previously reattached or detached greater than 10 cm, replace the door seal according



to the repair instructions in Elsa Web >> Body >> Body Exterior >> 57 Front Doors, Central Locking System >> Removal and Installation >>



Doors >> Door Seals.



Note:



In addition to the repair manual instructions for replacing the door seals observe the following: Thoroughly clean the area of seal attachment with



plastic cleaner D 009 401 04. Allow the area of seal attachment to dry completely (at least 5 minutes). Apply bonding agent D 355 205 A2 using a D



009 500 25 applicator to the seal attachment area. Allow to dry an additional 5 minutes.



If repairing the door seals, proceed as follows:



2. Ensure that the temperature of the door and outer door seal are not cooler than 70锟斤拷F (21锟斤拷C). This is vital to ensure optimum adhesion of the outer



door seal.



3. Thoroughly clean the bonding surfaces of the doors to be repaired with plastic cleaner D 009 401 04. Allow the bonding surfaces to dry



completely (at least 5 minutes). The bonding surfaces must be dry and free of any dust, grease, silicone or any other similar contaminant that might



compromise the adhesion.



4. Apply bonding agent D 355 205 A2 using a D 009 500 25 applicator in the area to be bonded. Allow the treated surface to dry an additional 5



minutes.



5. Thinly coat the outer door seal with rubber profile adhesive D 477 KD1 A2 in the area that has become detached.



284



6. Press the door seal lightly to the door surface and then detach it again (Figure 2). This ensures that the glue is distributed as evenly as possible on



the surfaces to be bonded.



7. Allow the now detached area to dry for 5 minutes.



8. After this time attach the seal firmly to the door surface. Roll over this area several times with special tool 3356 (or equivalent).



285



9. Apply force to the seal with the 3356 only at the base of the seal (area 3 shown in Figure 4).



10. Remove any residual adhesive that may be visible with adhesive remover D 002 000 A2.



Tip: The repaired door should not be closed for two hours. During this time, any freshly glued surfaces should not be tested by pulling on the seal to



see if they have bonded.



286



Warranty



All warranty claims submitted for payment must be in accordance with the Audi Warranty Policies and Procedures Manual. Claims are subject to



review or audit by Audi Warranty.



Required Parts and Tools



Additional Information



287



All parts and service references provided in this TSB are subject to change and/or removal. Always check with your Parts Department and service



manuals for the latest information.